Monitor SMART with Nightingale
Runs smartctl to read S.M.A.R.T. health attributes from HDDs, SSDs and NVMe drives, so you see reallocated sectors, temperature and wear before a disk actually dies.
Last reviewed
S.M.A.R.T. is the self-monitoring built into hard drives and SSDs. The Categraf smart input runs smartctl (and the nvme tool for NVMe devices) and emits smart_device for overall health plus smart_attribute for individual attributes: reallocated sectors, pending sectors, temperature, power-on hours, SSD wear and more.
The bundled rules watch the precursors of data loss: failed health checks, growing reallocated-sector counts and high temperature. The host needs smartmontools installed and Categraf needs permission to run smartctl, usually via passwordless sudo.
What's in the template
- 1 dashboard, 20 panels in total
- 6 alert rules, each with runbook steps
- 14 metric descriptions
- Categraf collector config:
input.smart
How to connect
-
Install Categraf, put the config below in
conf/input.smart/smart.toml, fill in your own address and credentials, and restart Categraf. The startup log printsinput: local.smart startedonce the plugin is loaded.# Read metrics from storage devices supporting S.M.A.R.T.[[instances]]## Optionally specify the path to the smartctl executable# path_smartctl = "/usr/bin/smartctl"## Optionally specify the path to the nvme-cli executable# path_nvme = "/usr/bin/nvme"## Optionally specify if vendor specific attributes should be propagated for NVMe disk case## ["auto-on"] - automatically find and enable additional vendor specific disk info## ["vendor1", "vendor2", ...] - e.g. "Intel" enable additional Intel specific disk info# enable_extensions = ["auto-on"]## On most platforms used cli utilities requires root access.## Setting 'use_sudo' to true will make use of sudo to run smartctl or nvme-cli.## Sudo must be configured to allow the telegraf user to run smartctl or nvme-cli## without a password.# use_sudo = true## Skip checking disks in this power mode. Defaults to## "standby" to not wake up disks that have stopped rotating.## See --nocheck in the man pages for smartctl.## smartctl version 5.41 and 5.42 have faulty detection of## power mode and might require changing this value to## "never" depending on your disks.# nocheck = "standby"## Gather all returned S.M.A.R.T. attribute metrics and the detailed## information from each drive into the 'smart_attribute' measurement.# attributes = true## Optionally specify devices to exclude from reporting if disks auto-discovery is performed.# excludes = [ "/dev/pass6" ]## Optionally specify devices and device type, if unset## a scan (smartctl --scan and smartctl --scan -d nvme) for S.M.A.R.T. devices will be done## and all found will be included except for the excluded in excludes.# devices = [ "/dev/ada0 -d atacam", "/dev/nvme0"]# devices = ["dev/nvme0 -d nvme", "/dev/nvme0"]## Timeout for the cli command to complete.timeout = "30s"## Optionally call smartctl and nvme-cli with a specific concurrency policy.## By default, smartctl and nvme-cli are called in separate threads (goroutines) to gather disk attributes.## Some devices (e.g. disks in RAID arrays) may have access limitations that require sequential reading of## SMART data - one individual array drive at the time. In such case please set this configuration option## to "sequential" to get readings for all drives.## valid options: concurrent, sequential# read_method = "concurrent" -
Open the integration center in Nightingale, find SMART, and import the dashboards and alert rules into a business group.
-
Imported rules start disabled. Check that the metrics are arriving first, then enable the rules one by one with thresholds that fit your environment.
Bundled dashboards
| Dashboard | Panels |
|---|---|
| S.M.A.R.T Dashboard | 20 |
Bundled alert rules
6 rules. Each lists its trigger condition (PromQL) and the steps to take when it fires. Thresholds are meant to be adjusted after import.
SMART device health status abnormal
Disk self-assessed overall health is FAILED, serious failure risk, handle immediately
S1 Critical · for 1 min · Trigger:
smart_device_health_ok == 0
Runbook:
- Run smartctl -a /dev/sdX for the full attribute list, focusing on Reallocated_Sector_Ct, Current_Pending_Sector and Offline_Uncorrectable;
- Immediately confirm the data on this disk has a replica or backup — this is the highest priority action;
- In a RAID array, check the array state and let it evict this disk and rebuild onto a hot spare;
- Schedule downtime to replace the disk and stop writing to it.
SSD media wearout >= 90%
SSD flash wearout is nearly exhausted and may fail at any time; back up data and replace the drive immediately
S1 Critical · for 1 min · Trigger:
smart_attribute_media_wear_percentage >= 90
Runbook:
- Run smartctl -a /dev/sdX and check Media_Wearout_Indicator / Percentage_Used together with Total_LBAs_Written;
- Combine with the write rate to estimate remaining life and plan the replacement window;
- Confirm the data on this disk has a replica and prepare the migration plan in advance;
- Review the source of write amplification (log level, frequent small writes, no TRIM) so the replacement does not repeat it.
Disk temperature exceeds 65 Celsius
Disk operating temperature too high, which accelerates aging or causes outright failure; check cooling immediately
S1 Critical · for 3 min · Trigger:
smart_device_temp_c > 65
Runbook:
- Run smartctl -a /dev/sdX and compare the temperature against the vendor's rated maximum;
- Check chassis airflow, fan speeds and dust in the filters, plus the room's ambient temperature;
- Check whether the bay layout is too dense and whether neighbouring disks are equally hot;
- Short term, reduce IO pressure on this disk (shift backups off peak, move hot data) to buy time.
CRC error count keeps growing within 1 hour
Growing CRC failures on the data link, a possible precursor of interface, cable or disk controller failure
S1 Critical · for 60 min · Trigger:
increase(smart_attribute_crc_error_count[1h]) > 0
Runbook:
- Run smartctl -a /dev/sdX and check how fast UDMA_CRC_Error_Count is growing;
- Take the machine down, reseat the SATA/SAS data and power cables, and preferably just replace the cable;
- After replacing the cable, watch whether the counter stops growing — SMART counters never reset, so judge by the delta, not the absolute value;
- If a new cable does not help, suspect the backplane or HBA and swap them one at a time.
SSD erase fail count growing
SSD flash block erase failures indicate aging flash chips and a risk of write failures
S1 Critical · for 1 min · Trigger:
increase(smart_attribute_erase_fail_count[1h]) > 0
Runbook:
- Run smartctl -a /dev/sdX and check Erase_Fail_Count together with the remaining Reallocated/Available_Reservd_Space;
- A shrinking spare block pool means the disk is near end of life — confirm the data has a replica immediately;
- Schedule a replacement rather than waiting for writes to fail outright;
- Reduce write pressure on the disk beforehand so it does not degrade faster.
SSD program fail count growing
SSD flash block program failures; flash chip health is degrading rapidly, back up data immediately
S1 Critical · for 1 min · Trigger:
increase(smart_attribute_program_fail_count[1h]) > 0
Runbook:
- Run smartctl -a /dev/sdX and check Program_Fail_Count together with the remaining spare block ratio;
- Immediately confirm the data on this disk has a replica or backup — this is the highest priority action;
- Schedule a replacement soon: program failures often come with a risk of silent data corruption;
- Before replacing it, make the disk read-only or move hot data off to stop further writes.
Metric reference
14 metrics, the ones the dashboards and rules above are built on.
| Metric | Meaning | Unit |
|---|---|---|
smart_attribute_crc_error_count | SMART CRC Error Count — The number of Cyclic Redundancy Check (CRC) failures during hard disk data transmission, reflecting the reliability of the data transmission link. | |
smart_attribute_end_to_end_error_detection_count | SMART End-to-End Error Detection Count — The number of end-to-end verification failures in internal hard disk data transmission, associated with the health of hard disk firmware or physical storage units. | |
smart_attribute_erase_fail_count | SMART Erase Fail Count — The number of failures when a Solid State Drive (SSD) erases flash memory blocks; an excessive number may indicate flash chip aging or an increase in bad blocks. | |
smart_attribute_host_reads | SMART Host Reads Count — The total number of times the operating system reads data from the hard disk, which is a statistical indicator of hard disk usage with no direct fault warning significance. | |
smart_attribute_media_wear_percentage | SMART Media Wear Percentage — A core indicator dedicated to Solid State Drives (SSDs) that reflects the wear level of flash memory chips; the closer the value is to 100%, the shorter the lifespan. | % |
smart_attribute_pll_lock_loss_count | SMART PLL Lock Loss Count — The number of times the hard disk clock synchronization module (Phase-Locked Loop, PLL) loses lock, which can cause data transmission timing errors. | |
smart_attribute_program_fail_count | SMART Program Fail Count — The number of failures when a Solid State Drive (SSD) writes data (program operation) to flash memory blocks, which is a core indicator of flash memory health. | |
smart_attribute_retry_buffer_overflow_count | SMART Retry Buffer Overflow Count — The number of times the data buffer overflows when the hard disk automatically retries after a read/write failure, indicating a decline in hard disk read/write performance or hardware failure. | |
smart_attribute_thermal_throttle_status | SMART Thermal Throttle Status — The state where the hard disk triggers automatic speed reduction protection due to high temperature (1=triggered, 0=not triggered), which will cause slow read/write speeds after triggering. | |
smart_attribute_timed_workload_timer | SMART Timed Workload Timer — Accumulates the operating time of the hard disk in a preset load mode, used to evaluate the long-term working intensity of the hard disk and assist in judging the wear rate. | s |
smart_attribute_wear_leveling_count | SMART Wear Leveling Count — An indicator dedicated to Solid State Drives (SSDs) that records the number of executions of the wear leveling algorithm to ensure uniform wear of flash memory blocks and extend lifespan. | |
smart_device_exit_status | SMART Device Exit Status — The exit status code of the hard disk SMART self-test; 0 means the self-test is completed normally, and a non-zero value indicates self-test interruption or abnormality. | |
smart_device_health_ok | SMART Device Health Status — The overall health status identifier of the hard disk; 1=healthy (no fault warning), 0=unhealthy (potential faults exist). | |
smart_device_temp_c | SMART Device Temperature — The current operating temperature of the hard disk (in ℃); the safe operating range for mainstream hard disks is 0-60℃, and prolonged overheating will accelerate hardware aging. | ℃ |
Related
- SMART template source: the raw JSON for dashboards, rules and collector config. Pull requests welcome.
- Categraf
smartplugin docs: every config option and the full metric list. - Import dashboards and alert rules
- Verify that metrics are stored