Monitor switches with zero config (Switch Legacy) in Nightingale

Give it a list of IPs and it detects the device model and collects CPU, memory and per-port traffic, errors and state; SNMP v2c only.

Last reviewed

The switch_legacy input is forked from swcollector and targets the "just get the switches in quickly" case. List IPs in the config (single addresses, subnets or ranges), and the input detects the device model and uses generic OIDs to collect CPU and memory usage plus traffic, packets, errors, discards and up/down state for every port. No OIDs to write.

It supports SNMP v2c only, so authentication is a single community string. Set switch_id_label to ident and each switch appears in Nightingale's host list keyed by its IP. For custom OIDs or SNMP v3, use the SNMP integration instead. The rules cover ports going down, traffic near bandwidth, rising errors and unreachable devices.

What's in the template​

  • 1 dashboard, 14 panels in total
  • 7 alert rules, each with runbook steps
  • Categraf collector config: input.switch_legacy

How to connect​

  1. Install Categraf, put the config below in conf/input.switch_legacy/switch_legacy.toml, fill in your own address and credentials, and restart Categraf. The startup log prints input: local.switch_legacy started once the plugin is loaded.

    # # collect interval
    # interval = "300s"

    switch_id_label = "ip"

    [mappings]
    "192.168.88.160" = "switch001.bj"
    "192.168.88.161" = "switch002.bj"

    [[instances]]
    # # interval = global.interval * interval_times
    # interval_times = 1

    # use global unique string to specify instance
    # labels = { region="beijing" }

    ips = [
    # "172.16.2.1",
    # "172.16.4/24",
    # "192.168.56.102-192.168.56.120"
    ]

    community = "public"

    # whether use index tag
    index_tag = false

    ignore_ifaces = ["Nu", "NU", "Vlan", "Vl"]

    concurrency_for_address = 1000
    concurrency_for_request = 4

    ping_enable = true
    ping_mode_fastping = true
    ping_timeout_ms = 300
    ping_retries = 4

    # true: use gosnmp, false: use snmpwalk
    snmp_mode_gosnmp = true
    snmp_timeout_ms = 1000
    snmp_retries = 5

    gather_ping_metrics = true
    gather_flow_metrics = true
    gather_cpu_metrics = true
    gather_mem_metrics = true
    gather_oper_status = false
    gather_pkt = false
    gather_broadcast_pkt = false
    gather_multicast_pkt = false
    gather_discards = false
    gather_errors = false
    gather_unknown_protos = false
    gather_out_qlen = false

    # ignore metrics if limit > 0 and collected value > limit
    speed_limit = 0
    pkt_limit = 0
    broadcast_pkt_limit = 0
    multicast_pkt_limit = 0
    discards_pkt_limit = 0
    errors_pkt_limit = 0
    unknown_protos_pkt_limit = 0
    out_qlen_pkt_limit = 0

    # [[instances.customs]]
    # metric = "AnyconnectSession"
    # tags = {}
    # oid = "1.3.6.1.4.1.9.9.392.1.3.35.0"

    # [[instances.customs]]
    # metric = "ConnectionStat"
    # tags = {}
    # oid = "1.3.6.1.4.1.9.9.147.1.2.2.2.1.5.40.6"

    # [[instances.customs]]
    # metric = "TempStatus"
    # tags = {}
    # oid = "1.3.6.1.4.1.9.9.13.1.3.1.3.1004"
  2. Open the integration center in Nightingale, find Switch (legacy), and import the dashboards and alert rules into a business group.

  3. Imported rules start disabled. Check that the metrics are arriving first, then enable the rules one by one with thresholds that fit your environment.

Bundled dashboards​

DashboardPanels
Network Switch14

Bundled alert rules​

7 rules. Each lists its trigger condition (PromQL) and the steps to take when it fires. Thresholds are meant to be adjusted after import.

Switch unreachable​

S1 Critical · for 2 min · Trigger:

switch_legacy_ping_up == 0

Runbook:

  1. Take the device identifier from the alert labels and double-check with ping and traceroute from a different machine to rule out a problem on the collector side;
  2. If it does ping from elsewhere, the problem is on the path from the collector; check the intermediate links and ACLs;
  3. If it does not ping at all, ask the data centre to check the power and status LEDs and try logging in over the console port;
  4. Once the device is confirmed failed, switch to the redundant link (check whether stacking/VRRP already failed over) and arrange a replacement.

Switch CPU utilization too high​

S2 Warning · for 5 min · Trigger:

switch_legacy_cpu_util > 80

Runbook:

  1. Log in to the device and run display cpu-usage (Huawei) or show processes cpu sorted (Cisco) to see which process is consuming CPU;
  2. High usage is commonly an ARP or broadcast storm, or heavy punting of packets to the CPU; check with display cpu-defend statistics;
  3. For a broadcast storm, locate the source port and configure storm-control, and check for a loop at the same time (STP state);
  4. If a protocol process is the consumer, check the routing table size and neighbour count and apply route summarisation if needed.

Switch memory utilization too high​

S2 Warning · for 5 min · Trigger:

switch_legacy_mem_util > 80

Runbook:

  1. Log in to the device and run display memory-usage or show memory statistics to see the breakdown;
  2. Check whether the MAC table, ARP table, and routing table sizes are approaching the device's specification limits;
  3. If entries are growing abnormally, check for a MAC flooding attack and configure port security to cap MAC learning per port;
  4. If this is genuine business growth, evaluate whether the device model needs upgrading and clean up unused configuration and ACLs.

Switch port flapping​

S2 Warning · for 1 min · Trigger:

changes(switch_legacy_if_oper_status[10m]) > 2

Runbook:

  1. Take the port identifier from the alert labels, log in to the device, and run display interface <port> to see the up/down count and the last transition time;
  2. Suspect the physical layer first: check whether the optical module's transmit and receive power (display transceiver diagnosis) are within thresholds and whether the fibre and connectors are loose;
  3. For copper ports, check cable quality and whether speed/duplex negotiation matches on both ends;
  4. Once physical problems are ruled out, check whether the peer device is restarting repeatedly, and shut down the port if necessary to stop it triggering network-wide reconvergence.

Switch port inbound errors​

S2 Warning · for 5 min · Trigger:

rate(switch_legacy_if_in_errors[5m]) > 1

Runbook:

  1. Take the port identifier from the alert labels and run display interface <port> to see the detailed CRC, Frame, and Giants error counters;
  2. Predominantly CRC errors are essentially always physical: replace the cable or fibre, clean the optical connectors, and confirm the cable length is within spec;
  3. Check that speed and duplex negotiation match on both ends, since a half/full duplex mismatch produces large numbers of collision errors;
  4. After replacing the cable, clear the counters with reset counters interface <port> and confirm they stop growing.

Switch port inbound bandwidth utilization too high​

S2 Warning · for 10 min · Trigger:

switch_legacy_if_in_speed_percent > 80

Runbook:

  1. Take the port identifier from the alert labels and run display interface <port> to confirm the live rate against the negotiated port speed;
  2. Use NetFlow/sFlow, or capture on the server side, to identify which workloads generate the traffic and rule out anomalies (backup jobs or data sync running in the wrong window);
  3. If this is genuine business growth, evaluate link aggregation (Eth-Trunk / port-channel) to add capacity;
  4. In the short term apply QoS rate limiting to non-critical traffic to protect the important flows.

Switch port outbound bandwidth utilization too high​

S2 Warning · for 10 min · Trigger:

switch_legacy_if_out_speed_percent > 80

Runbook:

  1. Take the port identifier from the alert labels and run display interface <port> to see the outbound rate and queue drop counters;
  2. For a saturated uplink, link aggregation is the most direct fix;
  3. Use traffic analysis to confirm whether high-volume workloads should be taking a different path, and adjust routing or apply traffic engineering if so;
  4. Before adding capacity, apply QoS queue rate limiting to secondary traffic to protect the critical business.